New Year Special Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dm70dm

NS0-093 NetApp Accredited Hardware Support Engineer Questions and Answers

Questions 4

How do you set environment variables to factory settings?

Options:

A.

set-defaults

B.

unsetenv all

C.

setenv factory

D.

wipeconfig

Buy Now
Questions 5

What are the two steps to unfail a disk in maintenance mode? (Choose two.)

Options:

A.

Reseat the disk.

B.

Remove it from the Failed Disk Registry.

C.

Use the "disk unfair command.

D.

Use the disk remove command.

Buy Now
Questions 6

While performing a health check on a cluster, you notice the following entries in the cluster event log:

NS0-093 Question 6

Referring to the exhibit, which of the following actions do you take?

Options:

A.

Sanitize the disk.

B.

Reseat the disk.

C.

Review the current firmware and known issues.

D.

Use diskcopy to copy the disk to a working spare.

Buy Now
Questions 7

Which two of the following methods are valid ways to access a node which is not booting? (Choose two.)

Options:

A.

node management port

B.

cluster management port

C.

Service Processor

D.

serial console

Buy Now
Questions 8

At what stage is a write acknowledged to a client?

Options:

A.

when the write is present in the local node RAM and NVRAM

B.

when the write has been flushed to disk

C.

when the write is present in the NVRAM on the local node and its HA partner

D.

when the write has been flushed from NVRAM to RAM

Buy Now
Questions 9

You are using wafliron on an aggregate named homedir on a production system.

When is the data on homedir available?

Options:

A.

when the administrator manually onlines the aggregate

B.

when wafliron is started

C.

after Phase 4 of wafliron is complete

D.

after the mounting phase of wafliron is complete

Buy Now
Questions 10

What is the recommended value for disk and CPU use when you plan an upgrade?

Options:

A.

less than 50%

B.

less than 90%

C.

less than 85%

D.

less than 70%

Buy Now
Questions 11

When you plan an ONTAP upgrade, which NetApp tool generates a detailed upgrade plan?

Options:

A.

ONTAP System Manager

B.

Active IQ Unified Manager

C.

Upgrade Advisor

D.

Active IQ Config Avisor

Buy Now
Questions 12

What is the default amount of time that a volume is available for recovery from the volume recovery queue following a volume deletion?

Options:

A.

12 hours

B.

48 hours

C.

72 hours

D.

24 hours

Buy Now
Questions 13

Following an unexpected takeover, the taken-over node is waiting for giveback. The administrator plans to perform a giveback with the option –cfo–only true.

What happens if this option is used?

Options:

A.

Only a simulation of the giveback is performed.

B.

Only the root aggregate is given back.

C.

Only SVM root volumes are sent back

D.

Only the data aggregates are sent back.

Buy Now
Questions 14

You have upgraded your cluster from ONTAP 9.5 software to ONTAP 9.7 software. After two days, you notice that the upgrade is causing issues. You decide to revert to ONTAP 9.5 software.

Which two actions do you need to complete before you revert? (Choose two.)

Options:

A.

Revert from ONTAP 9.7 software to ONTAP 9.6 software and then to ONTAP 9.5 software.

B.

Delete all Snapshot copies from the past two days.

C.

Reinstall your boot media and install ONTAP 9.5 software.

D.

Wipe your config and restore from backup.

Buy Now
Questions 15

You are reviewing the output of disk show and one of the disks is reporting a container type of “unknown”.

What is causing this status?

Options:

A.

The disk is not owned by a member of the high-availability (HA) pair.

B.

The disk is failed.

C.

The disk is in the maintenance center.

D.

The disk does not have an owner.

Buy Now
Questions 16

Which RAID type provides protection against three disk failures?

Options:

A.

RAID DP

B.

RAID-TEC

C.

RAID 5

D.

RAID 4

Buy Now
Questions 17

Which two NetApp tools should be used when troubleshooting the root cause of an unexpected controller reboot? (Choose two.)

Options:

A.

Active IQ Unified Manager

B.

Active IQ Digital Advisor

C.

ONTAP CLI

D.

ONTAP Mediator

E.

Active IQ Config Advisor

Buy Now
Questions 18

You have replaced a failed boot device. You perform boot_recovery and receive no errors. However, when the node reboots, it reports that it has no disks.

What are two possible causes? (Choose two.)

Options:

A.

The SAS cables were incorrectly reconnected after reinstalling the motherboard.

B.

The disks that are owned by this node have been marked as failed.

C.

The node is booting a lower version of ONTAP software than was last used.

D.

The interconnect is down.

Buy Now
Exam Code: NS0-093
Exam Name: NetApp Accredited Hardware Support Engineer
Last Update: Dec 20, 2024
Questions: 61

PDF + Testing Engine

$49.5  $164.99

Testing Engine

$37.5  $124.99
buy now NS0-093 testing engine

PDF (Q&A)

$31.5  $104.99
buy now NS0-093 pdf
dumpsmate guaranteed to pass
24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 27 Dec 2024