Winter Sale - Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dpm65

Hot Vendors

H19-311 Huawei Certified Pre-sales Associate- Data Center Facility Questions and Answers

Questions 4

Which of the following IP protection level does the UPS5000-E support? (Multiple Choice)

Options:

A.

IP20

B.

IP21

C.

IP41

D.

IP55

Buy Now
Questions 5

The output capacity of a single UPS is calculated on actual power when the actual load power is used for UPS configuration.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 6

What is the maximum number of cabinets used by the FusionModule800 respectively? ( )

Options:

A.

10

B.

9

C.

8

D.

6

Buy Now
Questions 7

If the voltage of a single battery in the battery string reaches (), the battery is in the danger state.

Options:

A.

1.67 V

B.

2.25 V

C.

2.35 V

D.

2.42 V

Buy Now
Questions 8

The failure warning feature for the key components of a UPS system changes post-event maintenance to pre-event maintenance, protecting loads from unexpected power failures. Which of the following components of the UPS2000-G support failure warning? (Multiple Choice)

Options:

A.

Fan

B.

Bus capacitor

C.

Output capacitor

D.

Battery

Buy Now
Questions 9

The UPS5000-A input mode is ().

Options:

A.

3Ph

B.

3Ph+N

C.

3Ph+N+PE

Buy Now
Questions 10

When the UPS5000-S is configured to satisfy N+2 modular redundancy configuration to carry 120 kW loads, a () UPS can be configured.

Options:

A.

160 kVA

B.

200 kVA

C.

240 kVA

D.

250 kVA

Buy Now
Questions 11

What UPS configuration method does the Fusion Mod ule800 support? ()

Options:

A.

N/2N

B.

N/N+1

C.

N/N+1/2N

Buy Now
Questions 12

The UPS5000-E has good scalability, supporting a maximum of () UPSs to be used in parallel.

Options:

A.

2

B.

4

C.

6

D.

8

Buy Now
Questions 13

What differentiated features does the FusionModule500 have over competing products? () (Multiple Choice)

Options:

A.

Integrated design of cooling and power

B.

Centralized management of multiple data centers

C.

Automatic startup of air conditioners when power supply recovers

D.

iBattery

Buy Now
Questions 14

The standard components and features in the typical configuration solution of the FusionModule800 include ().

Options:

A.

Temperature and humidity sensor, door status sensor, Huawei tablet, water sensor, video surveillance, and mobile app

B.

Smoke sensor, door status sensor, Huawei tablet, water sensor, simple cable trough, and video surveillance

C.

Smoke sensor, temperature and humidity sensor, Huawei tablet, alarm notification over short messages, mobile app, and easy cable trough

Buy Now
Questions 15

Under which of the following voltages can a 12 V single battery operate? (Multiple Choice)

Options:

A.

10.02 V

B.

13.5 V

C.

14.1V

D.

14.52 V

Buy Now
Questions 16

The UPS5000-A parallel signal cable does not adoptring connection, which reducessystem reliability because of the possibility of single-point failures.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

Are the air conditioners of the Fusion Mod ule800 connected to the back end of UPSs? ()

Options:

A.

Yes

B.

No

Buy Now
Questions 18

The rated loading capacity of a 3+0 parallel system is a maximum of () times the rated loading capacity of a single UPS.

Options:

A.

3

B.

2

C.

1.6

D.

1.2

Buy Now
Questions 19

Which of the following elements will affect the application of HVDC in the equipment room? (Multiple Choice)

Options:

A.

The standard is not complete, and multiple 240 V/336 V systems exist.

B.

Not all loads can use the DC power supply directly,

C.

The cost of DC circuit breaker components is high.

D.

The efficiency is low.

Buy Now
Questions 20

The UPS5000-E (25-125 kVA) supports a maximum of () power modules.

Options:

A.

4

B.

5

C.

6

D.

7

Buy Now
Questions 21

An industrial frequency UPS requires extra investment compared with a high frequency UPS, including (): (Multiple Choice)

Options:

A.

Equipment room area

B.

Bearing capacity (installation and construction)

C.

Cooling electricity cost

D.

D.G.

E.

Operating electricity cost

Buy Now
Questions 22

The UPS5000-E can realize convenient and simple 2N power supply system only by configuring a ().

Options:

A.

BSC cable

B.

Synchronized control

C.

BSC control board

D.

Parallel card

Buy Now
Questions 23

Which of the following statements are incorrect about the cable design? (Multiple Choice)

Options:

A.

An unlimited number of power cables can be used in parallel when the current is high.

B.

There is no need to derate because the UPS cable is designed based on the rated current.

C.

The UPS cable needs to consider the wiring capability of the UPS system terminal.

D.

Controlling the UPS AC cable voltage drop within 5% can satisfy the design requirements.

Buy Now
Questions 24

The built-in SNMP and ModBus card of the UPS5000-A reduce management investment costs for clients.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 25

Which of the following problems shall be considered when selecting the UPS cable? (Multiple Choice)

Options:

A.

Rated current of the UPS

B.

Rated operating voltage and insulating voltage of the power cable

C.

Voltage drop of the power cable in the route

D.

Number of the parallel cables

Buy Now
Questions 26

The UPS5000 is compatible with module and tower.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 27

Which of the following models has the widest input voltage range and is applicable to severe power grids?

Options:

A.

UPS5000-A

B.

Emerson NXP

C.

Eaton 9395

D.

APC Galaxy7000

Buy Now
Questions 28

Which of the following are the operating modes of the UPS2000-A series (1 kVA to 10 kVA)? ( ) (Multiple Choice)

Options:

A.

Normal mode

B.

Battery mode

C.

Bypass

D.

Maintenance bypass

Buy Now
Questions 29

The highest temperature in the local area is () when selects T3 air conditioning?

Options:

A.

30-35°C

B.

35-43°C

C.

43-55°C

D.

55-65°C

Buy Now
Questions 30

The efficiency of the UPS5000-E (25-75 kVA) power module is 96%.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 31

The battery voltage of the UPS2000-G is 240 V for the 6-10 kVA capacity models, and is 480 V for the 15 kVA and 20 kVA capacity models.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 32

In SCT, how many years is the longest lifetime for the spare part we could supply?

Options:

A.

2

B.

3

C.

4

D.

5

Buy Now
Questions 33

The UPS2000-G series (6 kVAto 20 kVA) features an industry-leading lightning protection design, with a lightning protection level of () and a surge protection level of (), which avoids 90% of failures caused by lightning strikes and offers reliable protection for the AC input ports on back-end devices.

Options:

A.

5 kA; 6 kV

B.

2kA;4kV

C.

2kA;6kV

D.

4kA;6kV

Buy Now
Exam Code: H19-311
Exam Name: Huawei Certified Pre-sales Associate- Data Center Facility
Last Update: Nov 17, 2024
Questions: 225

PDF + Testing Engine

$56  $159.99

Testing Engine

$42  $119.99
buy now H19-311 testing engine

PDF (Q&A)

$35  $99.99
buy now H19-311 pdf
dumpsmate guaranteed to pass
24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 22 Nov 2024