Winter Sale - Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dpm65

Note! The E20-542 Exam is no longer available.

E20-542 VMAX3 Solutions and Design Specialist Exam for Technology Architects Questions and Answers

Questions 4

What does it mean if a Storage Group is listed as "Critical" in Unisphere for VMAX?

Options:

A.

Storage Group performance is below the SLO target

B.

Hardware fault is impacting the Storage Groups

C.

Storage Group available capacity is running low

D.

Storage Groups belong to an SRP which is running low on space

Buy Now
Questions 5

A storage administrator has completed TimeFinder SnapVX testing. The administrator is unable to terminate the TimeFinder SnapVX snapshot of the test Storage Group.

What advice should be provided to the administrator?

Options:

A.

Check for linked targets

B.

Change the “Time to Live” setting

C.

Confirm there is available Reserved Capacity

D.

Issue the terminate command against the individual LUNs

Buy Now
Questions 6

A storage administrator wants to verify the state of the SLO compliance application data hosted on a VMAX3. Where can the information be found in Unisphere for VMAX?

Options:

A.

Storage Group Dashboard

B.

Storage Resource Pool

C.

Service Level Dashboard

D.

Hosts Dashboard

Buy Now
Questions 7

A customer wants to know if they need to set the SCSI3_persist_reserve attribute for their VMAX3 devices used in a clustered environment. What information should be provided?

Options:

A.

All VMAX3 thin devices have the attribute enabled by default.

B.

Attribute has been removed for VMAX3.

C.

Attribute will need to be manually set for each device.

D.

Attribute should not beused for clustered environments.

Buy Now
Questions 8

Two RDF groups from two VMAX3 arrays have been added to a RDF Consistency Group. SRDF/A Multi-Session Consistency (MSC) has been enabled for the Consistency Group. The RDF daemon has been started on a single host that has access to both the VMAX3 arrays.

What will happen if this host becomes unavailable?

Options:

A.

Cycle switching will stop

B.

SRDF mode will change to Adaptive Copy Disk

C.

RDF links will be suspended immediately

D.

SRDF pair state will become partitioned

Buy Now
Questions 9

Which SRDF remote replication licenses are available with VMAX3?

Options:

A.

Remote Replication Suite and SRDF Registered

B.

Remote Protection Suite and Application Protection Suite

C.

Remote Replication Suite and SRDF/Automated Replication

D.

Remote Protection Suite and SRDF Registered

Buy Now
Questions 10

When data consistency is not a requirement, which SRDF mode is preferred when replicating large volumes of data?

Options:

A.

SRDF/DM

B.

SRDF/A

C.

SRDF/S

D.

SRDF/CG

Buy Now
Questions 11

You are in the process of designing a VMAX3 solution with VMAX Sizer. Which parameters can be changed in a "What if Analysis"?

Options:

A.

Number of Disks, Cache Size, or IOPS Growth %

B.

Type of Disks, Number of I/O Modules, or Cache Size

C.

Platform Type, Number of Ports, or Software Suites

D.

Number of Disks, RAID Levels, or IOPS Growth %

Buy Now
Questions 12

You are designing an SRDF/A solution with BCSD and the results of the model are shown in the exhibit. The BCSD model was run with the following settings:

Source Array: VMAX 200K, 2-engine, 2 TB cache

Number of RA Ports: 4

Network Circuit: 450 MB/s

Required RPO: 5 minutes

Which conclusion can be made based on the modeling results?

Options:

A.

Inadequate number of RA ports

B.

Inadequate bandwidth

C.

Inadequate cache

D.

Inadequate paging disk space

Buy Now
Questions 13

How do Service Level Objectives (SLO) capacity compliance algorithms differ from Storage Resource Pools (SRP) capacity compliance algorithms?

Options:

A.

SLO capacity compliance ensures data is placed on the correct drive types.

SRP capacity compliance ensures data is placed on the correct SRP.

B.

SLO capacity compliance ensures data is placed on the correct SRP.

SRP capacity compliance ensures data is placed on the correct drive types.

C.

SLO capacity compliance ensures response time objectives are maintained.

SRP capacity compliance ensures performance metrics determine data placement.

D.

SLO capacity compliance ensures performance metrics determine data placement.

SRP capacity compliance ensures responsetime objectives are maintained.

Buy Now
Questions 14

After an SRDF failover operation, production work has been moved to the remote site. A large number of invalid tracks have accumulated that need to be synchronized back to the R1 volumes.

Which SRDF operation can reduce the re-synchronization time, while continuing production work on the remote site?

Options:

A.

Update

B.

Failback

C.

Restore

D.

Establish

Buy Now
Questions 15

In addition to Storage, Hosts, Performance, and Support, which other Unisphere for VMAX sections are available for selection of an individual VMAX3 array?

Options:

A.

Data Protection, Databases, and System

B.

Replication, Databases, and System

C.

Data Protection, Databases, and Applications

D.

Data Protection, System, and Applications

Buy Now
Questions 16

A VMAX3 parent Storage Group (SG) contains two child SGs: SG1 and SG2. What is a valid Host I/O limit setting for this configuration?

Options:

A.

Parent SG - 400,000

SG1 - 500,000, SG2 - 300,000

B.

Parent SG - 400,000

SG1 - 500,000, SG2–NOLIMIT

C.

Parent SG - 500,000

SG1 - 400,000, SG2 - NOLIMIT

D.

Parent SG - 500,000

SG1 - NOLIMIT, SG2 - 1,000,000

Buy Now
Questions 17

A TimeFinder SnapVX snapshot of source volumes has been linked to target volumes. The target volumes are being used for application testing.

What is recommended prior to a relink operation?

Options:

A.

Continue accessing the source volumes; stop accessing the target volumes

B.

Stop accessing the source volumes; continue accessing the target volumes

C.

Stop accessing the source and target volumes

D.

Continue accessing the source and target volumes

Buy Now
Questions 18

A VMware administrator has been tasked with managing storage for an ESXi cluster connected to a VMAX3 array. The VMware administrator is not familiar with Unisphere for VMAX and wants to use the VMware Web Client to provision VMFS datastores.

Which EMC product provides this functionality?

Options:

A.

VSI Plug-in

B.

VASA

C.

PowerPath

D.

SYMCLI

Buy Now
Questions 19

A VMAX3 Storage Group has Host I/O limits set at 10,000 IOPs. The Port Group contains four ports across different directors. The Dynamic Distribution is set to "Always".

What is the maximum IOPs the Storage Group can achieve in the event a switch port being used by one of the director ports fails but the director remains online?

Options:

A.

5,000

B.

7,500

C.

9,000

D.

10,000

Buy Now
Questions 20

What is the best practice sizing guideline for front-end (FA) utilization on a two-engine VMAX3?

Options:

A.

40%

B.

50%

C.

60%

D.

70%

Buy Now
Exam Code: E20-542
Exam Name: VMAX3 Solutions and Design Specialist Exam for Technology Architects
Last Update: Nov 27, 2023
Questions: 136
dumpsmate guaranteed to pass
24/7 Customer Support

DumpsMate's team of experts is always available to respond your queries on exam preparation. Get professional answers on any topic of the certification syllabus. Our experts will thoroughly satisfy you.

Site Secure

mcafee secure

TESTED 04 Dec 2024